A visionary company created by innovation

Dry eye syndrome is a condition that can become incapacitating if left untreated. Our studies with E-Eye demonstrate the effects of pulsed light in treating meibomian gland dysfunction. Our medical device can be used in cases of the evaporative form of dry eye.

E>Eye
E>Eye

E>Eye

Long-lasting and efficient treatment

Designed and manufactured in France by E-SWIN, a leading manufacturer of high-tech medical equipment Non-invasive, entirely painless and completely harmless Quick sessions and short treatment protocol.

HOW IT WORKS

  • The treatment only takes a few minutes per session
  • Patients are comfortably seated on a treatment chair
  • The protective white metallic eyemask is adjusted on the patient‘s eyes
  • Then, a specific treatment gel is applied on the cheekbone and the temporal areas
  • Four flashes are applied in the lower zone of both – starting on the inner canthus – and one flash in the temporal area to stimulate the upper glands
  • The gel is wiped off and the treatment is complete

The latest IRPL® technology

E-Eye is a medical device, which is FDA cleared under 510(k) K200616 for the following indication for use: E-Eye is a prescription device indicated for the treatment of Rosacea.

It generates Intense Regulated Pulsed Light by producing perfectly calibrated and homogeneously sequenced light pulses. The sculpted pulses are delivered under the shape of a train of pulses. The energy, spectrum and time period are precisely set to allow the best possible result.

tearcheck T
tearcheck T

tearcheck T

A revolution is born.

Designed to create a new standard for dry eye analysis with 2 completely new patented examinations (TFSE® & OSIE®).

tearcheck T provides the following exams:

  • Ocular Surface Inflammatory Evaluation
  • Tear Film Stability Evaluation / Non-Invasive Breakup Time
  • Abortive Blinking
  • Eye Redness
  • Demodex
  • Meibography IR
  • Eye Fitness Test
  • Corneal Topograhpy
Ocular Surface Inflammatory Risk Evaluation

Ocular Surface Inflammatory Risk Evaluation

  • Shows increased risk of inflammation
  • Exact dimension and score of the dryness
  • The new standard tool for eye surgeons and lense-opticians
Tear Film Stability Evaluation/Non-Invasive Breakup Time

Tear Film Stability Evaluation/Non-Invasive Breakup Time

  • Share the same imaging sequence
  • Shows the micro-movements of the tear film
  • Quick: Evaluation over 10 seconds
  • Gives the user an exact score of drynes
Abortive Blinking

Abortive Blinking

  • shows all blinks identified over the acquisition time (expected 1 minute).
  • determines the structure of the identified blinks: complete or incomplete blinks.
Eye Redness

Eye Redness

  • makes it possible to assess hyperemia caused by dry eye induced inflammatory processes
  • re-assess the patients as the treatment progresses
Demodex

Demodex

  • enlarged image capturing the base of the eyelashes
  • makes it possible to trace and visualize the signs of demodex presence
Meibography IR

Meibography IR

  • makes it possible to visualize the Meibomian Glands
  • shows the rate of gland loss (in %)
  • shows the morphology of the glands present
Tear Meniscus

Tear Meniscus

  • shows the height of the tear meniscus
  • two values are calculated: measurement below the iris center and thickest measurement
Eye Fitness Test

Eye Fitness Test

  • provides an overview of the patient’s eye fitness in everyday life